Apr 03, 2025
- Compañía
- Presione soltar
- I+D
Mar 06, 2025
Empresa / Nota de prensa
One factor that worsens allergy-like symptoms such as asthma and rhinitis
Tested and demonstrated with endotoxin
Osaka, Japan, March 6, 2025 – Panasonic Corporation (Panasonic) (https://holdings.panasonic/global/) today announced that it has demonstrated the inactivating effect of nanoe™ (hydroxyl radicals contained in water) technology on endotoxin, which causes aggravation of allergy-like symptoms such as asthma and rhinitis, under the supervision of Masafumi Mukamoto, Professor Emeritus of Osaka Metropolitan University and Visiting Researcher at the University of Hyogo.
According to the 2023 Patient Survey published by the Ministry of Health, Labour and Welfare, the total number of asthma patients in Japan is approximately 1.85 million.*1 A wide variety of factors are also known to contribute to exacerbation of asthma. Of these, academic studies suggest that endotoxin is one of contributing factors to the aggravation of allergy-like symptoms such as asthma and rhinitis,*2, *3 and its presence in house dust*4 and in air pollutants such as PM 2.5 and Asian sand dust*5, *6 has been confirmed. Endotoxin is also known they derive from gram-negative bacteria such as Escherichia coli and are resistant to alcohol and heat, rendering inactivation by general disinfection methods more difficult.
Panasonic has demonstrated the inhibitory effect of nanoe™ (hydroxyl radicals contained in water) technology on 20 types of bacteria, and has also partially identified its inhibitory mechanism on bacteria.*7 In this study, in order to verify its effectiveness against bacterial toxins, Panasonic has newly verified its effects against endotoxin, which is resistant to alcohol and heat. The results demonstrated that exposure to nanoe™ (hydroxyl radicals contained in water) had an inactivation rate of 99% or higher. Note that this verification was conducted under test conditions and does not attest to effectiveness in actual usage spaces. Also, the test was conducted to verify effectiveness on chemical substances that contribute to the worsening of symptoms, and not on the worsening of the symptoms themselves.
Panasonic is committed to further advancing nanoe™ (hydroxyl radicals contained in water) technology and pursuing its possibilities in order to help society by providing safe, secure spaces.
Figure 1: Test Overview
Figure 2: Test Overview
Below are the results of confirming the residual endotoxin activity rate*10 for standard endotoxin exposed to nanoe™ (hydroxyl radicals contained in water) for 48 hours, treated with alcohol, and treated with heat, respectively. Only nanoe™ (hydroxyl radicals contained in water) technology showed an inactivation effect of 99% or more.
Figure 3: Residual activity rates of standard endotoxin after exposure to nanoe™
(hydroxyl radicals contained in water), alcohol treatment, and heat treatment*10
The results of confirming the residual endotoxin activity rate*10 using E. coli exposed to nanoe™ (hydroxyl radicals contained in water) for 48 hours are described below. nanoe™ (hydroxyl radicals contained in water) technology showed an inactivation effect of 99% or more.
Figure 4: Residual endotoxin activity rate using E. coli after exposure to nanoe™ (hydroxyl radicals contained in water)
Endotoxin is a toxin that exists on the surface of gram-negative bacteria such as E. coli. It has various biological activity, and has been suggested to aggravate allergy-like symptoms such as asthma and rhinitis. Endotoxin has been reported as present in air pollutants such as PM 2.5 and Asian sand dust, as well as house dust. Particular attention should be paid to Asian sand dust, as the number of days it is observed increases during spring. In addition, endotoxin is known to be resistant to alcohol and heat, so even if bacterial sterilization is performed, it may not be possible to inactivate endotoxin. Thus, I think it is significant that inactivation of endotoxin by nanoe™ (hydroxyl radicals contained in water) technology was demonstrated in this test.
*Edited from comments received at the request of Panasonic.
The atomizing electrode is cooled by a Peltier element, which condenses moisture in the air to create water. Afterwards, a high voltage is applied across the atomizing electrode and the opposite electrode to generate nanoe™ (hydroxyl radicals contained in water) contained in water that contain hydroxyl radicals of approximately 5 to 20 nanometers in size. (Figure 5)
Figure 5. nanoe™ (hydroxyl radicals contained in water) generator
Notes:
*1: Reference: "2023 Patient Survey" Ministry of Health, Labour and Welfare. https://www.mhlw.go.jp/toukei/saikin/hw/kanja/23/index.html
*2: Reference: M. Berger et al. "Lipopolysaccharide amplifies eosinophilic inflammation after segmental challenge with house dust mite in asthmatics," Allergy, vol. 70, No. 3, pp. 257-264, 2014.
*3: Reference: Braga CR et al. "Nasal provocation test (NPT) with isolated and associated dermatophagoides pteronyssinus (Dp) and endotoxin lipopolysaccharide (LPS) in children with allergic rhinitis (AR) and nonallergic controls," J Investig Allergol Clin Immunol., vol. 14, No. 2, pp. 142-8, 2004.
*4: Reference: Peter S. Thorne et al. "Endotoxin Exposure Is a Risk Factor for Asthma The National Survey of Endotoxin in United States Housing," American Journal of Respiratory and Critical Care Medicine, vol. 172, No. 11, pp. 1371-1377, 2005.
*5: Reference: Takamichi Ichinose, "Progress of the research on air pollution (PM 2.5, Asian sand dust, etc.) and allergy," Japanese Journal of Allergology, vol. 63, No. 8, pp. 1085-1094, 2014.
*6: Reference: Yahao Ren et al. "Enhancement of OVA-induced murine lung eosinophilia by co-exposure to contamination levels of LPS in Asian sand dust and heated dust," Allergy Asthma Clin Immunol., vol. 10, No. 1, pp. 30, 2014.
*7: [Press Release] Visual Imaging of Bacterial Inhibition Mechanism by Hydroxyl Radicals Contained in Water in Collaboration with Harvard University (March 29, 2012)
*8: Endotoxin testing and data acquisition were conducted in cooperation with FUJIFILM Wako Bio Solutions Corporation.
*9: Endotoxin testing was conducted in accordance with the "General Rules" and "General Testing Methods" of the Revised Japanese Pharmacopoeia, 18th Edition.
*10: Panasonic's own calculation of residual endotoxin activity rate = (activity after treatment/untreated activity) x 100
◆A summary of this press release can be found here:
https://www.panasonic.com/global/consumer/nanoe/ja/topics/250306.html
◆Results of research into nanoe™ (hydroxyl radicals contained in water) technology to date can be found here:
https://www.panasonic.com/global/consumer/nanoe/ja.html
Living Appliances and Solutions Company, Panasonic Corporation
Public Relations, Corporate Policy Department, Corporate Planning Center
Email: las-pr@gg.jp.panasonic.com
Living Appliances and Solutions Company, Panasonic Corporation
Unidad de Negocio de Productos de Dispositivos, División de Negocio de Belleza y Cuidado Personal
Teléfono: +81-(0)749-27-0485 (disponible de 9:30 a 17:00 horas, excepto sábados, domingos y festivos)
Acerca de Panasonic Corporation Panasonic Corporation ofrece productos y servicios para una variedad de entornos, desde hogares hasta tiendas, oficinas y ciudades. Cinco negocios conforman la base de Panasonic Corporation: Living Appliances and Solutions Company, Heating & Ventilation A/C Company, Cold Chain Solutions Company, Electric Works Company y China and Northeast Asia Company. La compañía operativa reportó ventas netas consolidadas de 3.494,4 billones de yenes para el año fiscal que finalizó el 31 de marzo de 2024. Panasonic Corporation se compromete a cumplir la misión de Tecnología e Ideas para la Vida: Para el bienestar de las personas, la sociedad y el planeta, y abraza la visión de ser el mejor aliado de su vida con tecnología e innovación centradas en el ser humano. Más información sobre Panasonic: https://www.panasonic.com/global/about/ |
El contenido de este sitio web es preciso en el momento de su publicación, pero puede estar sujeto a cambios sin previo aviso.
Por lo tanto, tenga en cuenta que estos documentos pueden no contener siempre la información más actualizada.
Tenga en cuenta que las versiones en alemán, francés y chino son traducciones automáticas, por lo que la calidad y la precisión pueden variar.